QL Plus Series User Guide
8. Yellow error light or flashing:
•Noapplicationorapplicationcorrupted:reloadprogram.
•Ifusingwirelesscommunications:ashingindicatoris
normal while data is being transmitted or received.
9. Yellow error light always on, or flashing:
•Checkthatmediaisloadedandthattheprintheadisclosed
and securely latched.
10. Skips labels:
•Checkmediafortopofformsensemarkorlabelgap.
•Checkthatthemaximumprinteldhasnotbeenexceeded
on label.
•Ensurebarorgapsensorisnotblockedor
malfunctioning
11. Communication error:
•Checkmediaisloaded,headisclosedanderror
light is off.
•Checkbaudrate.
•Replacecabletoterminal.
12. Label jam:
•Openheadreleaselatchandmediacover.
•Generouslyapplyalcoholtoprinterinareaof
jammed label.
13. Blank LCD screen (only for units with LCD control
panel)
•Noapplicationloadedorapplicationcorrupted:reload
program.